To use this function you have to enable JavaScript and allow popup windows for this domain.
 
Analytical Columns

YMC Triart hybrid struktur

YMC-Triart C18
 

 
 


First choice column for method develompent

YMC-Triart

Conventional hybrid silica-based ODS columns tend to be less hydrophobic than silica-
based columns. YMC-Triart C18 has a higher carbon load, making its hydrophobicity comparable to standard ODS columns, making it a ”versatile first-choice“ column
for method development.

  nach oben  

LC/MS compatibility

YMC-Triart C18, LC/MS compatibility
Column: 5 μm, 50 x 2.0 mm ID
Eluent: A) water / fomic acid (100/0.1)
B) acetonitrile /formic acid (100/0.1) 5% B (0-1 min), 5-100% B (1-5 min), 100% B (5-10 min), 100-5% B (10-10.1 min), 5% B (10.1-12.5 min)
Flow rate: 0.4 ml/min
Temperature: 40 °C
Detection: ESI positive, TIC (Mass Range: 50-1000)
Column bleeding, caused by the fragments of stationary phase, is the main reason for background noise and limitations on detection limits. No bleed is observed in the test of total ion current (TIC) measured by LC/MS with blank or with YMC-Triart C18. So in terms of the signalnoise ratio (S/N ratio), YMC-Triart C18 can be expect to not only reduce the background noise but to also increase the sensitivity of the analysis.

  nach oben  

Betablockers

YMC-Triart C18 - Application Betablockers

Column: TA12SP90502PT
Dimension: 50 x 2.0 mm ID
Eluent: A) 20 mM NH4CH3COOH + ammonia (pH 9.0)
B) acetonitrile
Gradient: 25% B (1.0 min); 75% B (1-6 min)
Flow rate: 0.35 ml/min
Detection: UV at 254 nm
Pressure: 450 bar
Temperature: 40 °C
Injection: 1 μl

  nach oben  

Barbiturates in human serum

YMC Triart

Column: YMC-TriArt C18 (5 μm, 12 nm)
Dimension: 50 x 2.0 mm ID
Eluent: A) 20 mM HCOONH4-NH3 (pH 9.5)
B) methanol
Grandient: 0-90% B (0-7 min)
Flow rate: 0.2 ml/min
Temperature: 25 °C
Detection: UV at 240 nm
Injection: 1 μl

  nach oben  

Soy isoflavones in supplement

YMC Triart Soy iso avones in supplement

Column: YMC-TriArt C18 (3 μm, 12 nm) Flow rate: 0.4 ml/min
Dimension: 50 x 2.0 mm ID Temperature: 25 °C
Eluent: A) acetonitrile / water / HCOOH (10/90/0.1)
B) acetonitrile / water / HCOOH (60/40/0.1)
Detection: UV at 254 nm
Grandient: 5-40% B (0-12 min) Injection: 2 μl

 

Application courtesy of YMC Co., Ltd.


  nach oben  

Trademarks
Zorbax Eclipse Plus C18 RRHD C18 is a trademark of Agilent Technologies Inc.
Capcell Pak C18 AQ is a trademark of Shiseido Co., Ltd.
Inertsil and Inertsil ODS-3 are trademarks of GL Sciences Inc.
Acquity BEH C18, Atlantis T3, XBridge C18, XTerra MS C18 and SunFire C18 are trademarks of Waters Corp.
Gemini C18, Gemini NX C18 and Kinetex C18 are trademarks of Phenomenex, Inc.
Hypersil Gold is a trademark of Thermo Fisher Scientific Inc.
Eternity C18 is a trademark of EKA Chemicals AB.
Ascentis Express C18 is a trademark of Sigma-Aldrich Co.
TSKgel ODS-100S is a trademark of Tosoh Bioscience Inc.

The publication of the image and data material is courtesy of YMC Co., Lt



© 2006 -2012 YMC Europe GMBH

 